Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Easun Power 3.2 SGH II : can't find values for #113

Open
carmelo42 opened this issue Nov 23, 2023 · 0 comments
Open

Easun Power 3.2 SGH II : can't find values for #113

carmelo42 opened this issue Nov 23, 2023 · 0 comments

Comments

@carmelo42
Copy link

Hello,

I can't find values for qpiri, qpiws, qmod and qpigs for my Easun Power 3.2 SGH II.

I have tried this :

# This allows you to modify the buffersize for the qpiri command
qpiri=98

# This allows you to modify the buffersize for the qpiws command
qpiws=40

# This allows you to modify the buffersize for the qmod command
qmod=5

# This allows you to modify the buffersize for the qpigs command
qpigs=110

And here is what I get :

root@ced214cde071:/opt/inverter-cli/bin# ./inverter_poller -d -1
Thu Nov 23 14:39:45 2023 INVERTER: Debug set
Thu Nov 23 14:39:45 2023 INVERTER: Current CRC: 49 C1
Thu Nov 23 14:39:45 2023 INVERTER: QMOD reply size (5 bytes)
Thu Nov 23 14:39:45 2023 INVERTER: QMOD: 5 bytes read: (L
Thu Nov 23 14:39:45 2023 INVERTER: QMOD query finished
Thu Nov 23 14:39:45 2023 INVERTER: Current CRC: B7 A9
Thu Nov 23 14:39:48 2023 INVERTER: QPIGS read timeout
Thu Nov 23 14:39:48 2023 INVERTER: QPIGS reply too short (0 bytes)
Thu Nov 23 14:39:48 2023 INVERTER: Current CRC: F8 54
Thu Nov 23 14:39:48 2023 INVERTER: QPIRI reply size (98 bytes)
Thu Nov 23 14:39:48 2023 INVERTER: QPIRI: 98 bytes read: (230.0 13.9 230.0 50.0 13.9 3200 3000 24.0 23.0 22.0 29.0 29.0 2 20 020 1 0 2 6 01 0 0 27.0 0 1
Thu Nov 23 14:39:48 2023 INVERTER: QPIRI query finished
Thu Nov 23 14:39:48 2023 INVERTER: Current CRC: B4 DA
Thu Nov 23 14:39:51 2023 INVERTER: QPIWS read timeout
Thu Nov 23 14:39:51 2023 INVERTER: QPIWS reply too short (0 bytes)
Thu Nov 23 14:39:56 2023 INVERTER: Current CRC: B7 A9
Thu Nov 23 14:39:56 2023 INVERTER: QPIGS reply size (110 bytes)
Thu Nov 23 14:39:56 2023 INVERTER: QPIGS: 110 bytes read: (240.0 49.9 240.0 49.9 0167 0049 005 457 29.00 001 100 0023 0000 000.0 00.00 00000 00010101 00 00 00001 110
Thu Nov 23 14:39:56 2023 INVERTER: QPIGS query finished
Thu Nov 23 14:39:56 2023 INVERTER: Current CRC: B4 DA
INVERTER: ampfactor from config is 1.00
INVERTER: wattfactor from config is 1.01
{
  "Inverter_mode":3,
  "AC_grid_voltage":240.0,
  "AC_grid_frequency":49.9,
  "AC_out_voltage":240.0,
  "AC_out_frequency":49.9,
  "PV_in_voltage":0.0,
  "PV_in_current":0.0,
  "PV_in_watts":0.0,
  "PV_in_watthour":0.0000,
  "SCC_voltage":0.0000,
  "Load_pct":5,
  "Load_watt":49,
  "Load_watthour":1.6333,
  "Load_va":167,
  "Bus_voltage":457,
  "Heatsink_temperature":23,
  "Battery_capacity":100,
  "Battery_voltage":29.00,
  "Battery_charge_current":1,
  "Battery_discharge_current":0,
  "Load_status_on":1,
  "SCC_charge_on":0,
  "AC_charge_on":1,
  "Battery_recharge_voltage":23.0,
  "Battery_under_voltage":22.0,
  "Battery_bulk_voltage":29.0,
  "Battery_float_voltage":29.0,
  "Max_grid_charge_current":20,
  "Max_charge_current":20,
  "Out_source_priority":0,
  "Charger_source_priority":2,
  "Battery_redischarge_voltage":2579850948650221782946201194201088.0,
  "Warnings":""
}
Thu Nov 23 14:39:56 2023 INVERTER: All queries complete, exiting loop.
root@ced214cde071:/opt/inverter-cli/bin#

I can see some config topics in MQTT bus, but nothing in Home Assistant in the MQTT devices.