-
Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathA3COM-HUAWEI-LswMix-MIB
153 lines (136 loc) · 4.36 KB
/
A3COM-HUAWEI-LswMix-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
-- ------------------------------------------------------------------
--
-- Description: HuaWei Lan Switch Dual Main Control MIB
--
-- Version: V1.2
-- History:
-- Revise History: 1) 2003-03-27 Fuzhenyu created
-- V1.1 2004-10-12 updated by gaolong
-- Import NOTIFICATION-TYPE.
-- MAX-ACCESS clause value from write-only to read-write.
-- Substitute hwsMixTrapMib MODULE-IDENTITY with hwsMixTrapMib OBJECT IDENTIFIER.
-- V1.2 2005-11-14
-- updated by Chen Xi
-- Modify description of all objects except hwLswXSlotTable and hwLswXSlotEntry.
-- updated by Yu Lan
-- Add process(3) value for hwLswMainCardBoardStatus.
-- Add hwLswCrossBarStatus.
-- ------------------------------------------------------------------
--
-- ------------------------------------------------------------------
--
-- Variable imported
--
-- ------------------------------------------------------------------
A3COM-HUAWEI-LswMix-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
hwLswFrameIndex,hwLswSlotIndex
FROM A3COM-HUAWEI-DEVICE-MIB
lswCommon
FROM A3COM-HUAWEI-OID-MIB;
-- the document include the private data about device
-- ******************************beginning ******************************
--
-- ------------------------------------------------------------------
hwLswMix MODULE-IDENTITY
LAST-UPDATED "200106290000Z"
ORGANIZATION ""
CONTACT-INFO
""
DESCRIPTION
""
REVISION "200106290000Z"
DESCRIPTION
""
::= { lswCommon 17 }
-- the document include the private data about device mix
hwLswLastSwitchDate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the date of the most recent change
to the mpu(Main Processing Unit). "
::= { hwLswMix 1 }
hwLswLastSwitchTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the time of the most recent change
to the mpu. "
::= { hwLswMix 2 }
hwLswMpuSwitchsNum OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total times of the mpu switched
since the system start up. "
::= { hwLswMix 3 }
hwLswMpuSwitch OBJECT-TYPE
SYNTAX INTEGER{
switch(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object will immediately switch the standby mpu
to master mpu. Read is not supported. "
::= { hwLswMix 4 }
-- the document include the private data about main card
hwLswXSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwLswXSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The source main table."
::= { hwLswMix 5 }
hwLswXSlotEntry OBJECT-TYPE
SYNTAX HwLswXSlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the source main table."
INDEX { hwLswFrameIndex, hwLswSlotIndex }
::= { hwLswXSlotTable 1 }
HwLswXSlotEntry ::=
SEQUENCE {
hwLswMainCardBoardStatus INTEGER,
hwLswCrossBarStatus INTEGER
}
hwLswMainCardBoardStatus OBJECT-TYPE
SYNTAX INTEGER{
master(1),
standby(2),
process(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value describes whether the board is master, standby or process.
master and standby are the possible states for the mpu, while process
indicates the state of lpu(Line Processing Unit)"
::= { hwLswXSlotEntry 1 }
hwLswCrossBarStatus OBJECT-TYPE
SYNTAX INTEGER{
master(1),
standby(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value describes whether the crossbar is master or standby. It is
master when it's in the master mpu board, standby when in the standby mpu.
But both crossbars in mpus are master when the device in load-balance mode."
::= { hwLswXSlotEntry 2 }
hwsMixTrapMib OBJECT IDENTIFIER ::= { hwLswMix 10 }
hwSlaveSwitchOver NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"An hwSlaveSwitchOver trap signifies that the action of
standby mpu switching to master has completed. "
::= { hwsMixTrapMib 1 }
END