-
Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathA3COM-HUAWEI-FR-QOS-MIB
616 lines (532 loc) · 17.6 KB
/
A3COM-HUAWEI-FR-QOS-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
-- =================================================================
-- Copyright (C) 2004 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description:This mib file is used for management of huawei Class Based
-- FR QoS information.
-- Reference:
-- Version: V1.1
-- History:
-- V1.0 caolei,2004.7.12,publish
-- V1.1 2004-10-12 updated by gaolong
-- Relocate hwFrQoSMib MODULE-IDENTITY.
-- =================================================================
A3COM-HUAWEI-FR-QOS-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwQoS
FROM A3COM-HUAWEI-OID-MIB
ifIndex
FROM RFC1213-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus
FROM SNMPv2-TC;
hwFrQoSMib MODULE-IDENTITY
LAST-UPDATED "200407120000Z" -- JULY 12, 2004 at 00:00 GMT
ORGANIZATION
"Huawei Technologies co.,Ltd."
CONTACT-INFO
" R&D BeiJing, Huawei Technologies co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
Zip:100085
Http://www.huawei.com
E-mail:[email protected] "
DESCRIPTION
"This MIB contains objects to
Manage configuration and Monitor running state
for Class Based FR QoS feature.
*********************************
MIB Tables
**********************************
This MIB consists of the following tables:
1 : hwFrClassCfgInfoTable
2 : hwCirCfgInfoTable
3 : hwIfApplyFrClassTable
4 : hwPvcApplyFrClassTable
5 : hwFrPvcBandwidthTable
5 : hwRTPFrClassApplyTable
6 : hwRTPFrPvcQueueRunInfoTable
"
::= { hwQoS 3 } -- need modification later
--
--type definitions in the policy
--
--Direction
CirAllowDirection ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Packet Direction apply on."
SYNTAX INTEGER {
inbound (1),
outbound (2),
inboundAndOutbound (3)
}
--
--end of type definitions in policy
--
--
-- Node definitions
--
hwFrQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSMib 1 }
--hwFrClassObjects
hwFrClassObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 1 }
-- Fr Class Next Index
hwFrClassIndexNext OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to be used for
hwFrClassIndex when creating rows in the
hwFrClassCfgInfoTable. Begin with 0.
"
::= { hwFrClassObjects 1 }
-- Fr Class
hwFrClassCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwFrClassCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Fr Class configuration information."
::= { hwFrClassObjects 2 }
hwFrClassCfgInfoEntry OBJECT-TYPE
SYNTAX HwFrClassCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Class Configuration Information Entry."
INDEX { hwFrClassIndex }
::= { hwFrClassCfgInfoTable 1 }
HwFrClassCfgInfoEntry ::=
SEQUENCE {
hwFrClassIndex
Integer32,
hwFrClassName
OCTET STRING,
hwFrClassRowStatus
RowStatus
}
hwFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0."
::= { hwFrClassCfgInfoEntry 1 }
hwFrClassName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of Fr Class."
::= { hwFrClassCfgInfoEntry 2 }
hwFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwFrClassCfgInfoEntry 3 }
-- Cir Allow on the Fr Class
hwCirAllowCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCirAllowCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of DCE allowed rate Configuration information."
::= { hwFrClassObjects 3 }
hwCirAllowCfgInfoEntry OBJECT-TYPE
SYNTAX HwCirAllowCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DCE allowed ratee Configuration Information Entry."
INDEX { hwCirAllowFrClassIndex,
hwCirAllowDirection}
::= { hwCirAllowCfgInfoTable 1 }
HwCirAllowCfgInfoEntry ::=
SEQUENCE {
hwCirAllowFrClassIndex
Integer32,
hwCirAllowDirection
CirAllowDirection,
hwCirAllowValue
Integer32,
hwCirAllowRowStatus
RowStatus
}
hwCirAllowFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
::= { hwCirAllowCfgInfoEntry 1 }
hwCirAllowDirection OBJECT-TYPE
SYNTAX CirAllowDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Packet Direction.
inbound (1)
outbound (2)
inbound and outbound (3)
"
::= { hwCirAllowCfgInfoEntry 2 }
hwCirAllowValue OBJECT-TYPE
SYNTAX Integer32(1..45000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"DCE allowed rate (value greater than CIR)
Unit : Bits per second.
Value : <1-45000000> ."
::= { hwCirAllowCfgInfoEntry 3 }
hwCirAllowRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwCirAllowCfgInfoEntry 4 }
-- Cir on the Fr Class
hwCirCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCirCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Committed Information Rate Configuration information."
::= { hwFrClassObjects 4 }
hwCirCfgInfoEntry OBJECT-TYPE
SYNTAX HwCirCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Committed Information Rate Configuration Information Entry."
INDEX { hwCirFrClassIndex }
::= { hwCirCfgInfoTable 1 }
HwCirCfgInfoEntry ::=
SEQUENCE {
hwCirFrClassIndex
Integer32,
hwCirValue
Integer32,
hwCirRowStatus
RowStatus
}
hwCirFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of Fr Class. Begin with 0.Equal to hwFrClassIndex"
::= { hwCirCfgInfoEntry 1 }
hwCirValue OBJECT-TYPE
SYNTAX Integer32(1000..45000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" CIR in packet output direction ,bps.
Value : <1000-45000000>."
::= { hwCirCfgInfoEntry 2 }
hwCirRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwCirCfgInfoEntry 3 }
-- Fr Class Instance on interface Table
hwIfApplyFrClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwIfApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of QoS Fr Class instance."
::= { hwFrClassObjects 5 }
hwIfApplyFrClassEntry OBJECT-TYPE
SYNTAX HwIfApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FrClass applied on interface Configuration Information Entry."
INDEX { hwIfApplyFrClassIfIndex }
::= { hwIfApplyFrClassTable 1 }
HwIfApplyFrClassEntry ::=
SEQUENCE {
hwIfApplyFrClassIfIndex
Integer32,
hwIfApplyFrClassIndex
Integer32,
hwIfApplyFrClassRowStatus
RowStatus
}
hwIfApplyFrClassIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface Index, equal to ifIndex."
::= { hwIfApplyFrClassEntry 1 }
hwIfApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Fr Class, equal to hwFrClassIndex"
::= { hwIfApplyFrClassEntry 2 }
hwIfApplyFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwIfApplyFrClassEntry 3 }
-- Fr Class Instance on fr pvc Table
hwPvcApplyFrClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwPvcApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of QoS Fr Class instance."
::= { hwFrClassObjects 6 }
hwPvcApplyFrClassEntry OBJECT-TYPE
SYNTAX HwPvcApplyFrClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Class applied on FR Pvc Configuration Information Entry."
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwPvcApplyFrClassTable 1 }
HwPvcApplyFrClassEntry ::=
SEQUENCE {
hwPvcApplyFrClassIfIndex
Integer32,
hwPvcApplyFrClassDlciNum
Integer32,
hwPvcApplyFrClassIndex
Integer32,
hwPvcApplyFrClassRowStatus
RowStatus
}
hwPvcApplyFrClassIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Interface Index, equal to ifIndex."
::= { hwPvcApplyFrClassEntry 1 }
hwPvcApplyFrClassDlciNum OBJECT-TYPE
SYNTAX Integer32 (16..1007)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr DLCI number."
::= { hwPvcApplyFrClassEntry 2 }
hwPvcApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Fr Class, equal to hwFrClassIndex"
::= { hwPvcApplyFrClassEntry 3 }
hwPvcApplyFrClassRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus. Three actions are used: active,
createAndGo, destroy"
::= { hwPvcApplyFrClassEntry 4 }
-- bandwidth parameter on interface
hwFrPvcBandwidthTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwFrPvcBandwidthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Running statistics for bandwidth.
"
::= { hwFrClassObjects 7 }
hwFrPvcBandwidthEntry OBJECT-TYPE
SYNTAX HwFrPvcBandwidthEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bandwidth Running statistics"
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwFrPvcBandwidthTable 1 }
HwFrPvcBandwidthEntry ::=
SEQUENCE {
hwFrPvcBandwidthMaxReservedBW
Integer32,
hwFrPvcBandwidthAvailable
Integer32
}
hwFrPvcBandwidthMaxReservedBW OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max reserved bandWidth. Unit : Kbps"
::= { hwFrPvcBandwidthEntry 1 }
hwFrPvcBandwidthAvailable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Available bandWidth. Unit : Kbps"
::= { hwFrPvcBandwidthEntry 2 }
--hwRTPQoSObjects
hwRTPQoSObjects OBJECT IDENTIFIER ::= { hwFrQoSObjects 2 }
-- Rtpq applied on the Fr Class
hwRTPFrClassApplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwRTPFrClassApplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of RTP(Realtime Transport Protocol) Queue instance."
::= { hwRTPQoSObjects 1 }
hwRTPFrClassApplyEntry OBJECT-TYPE
SYNTAX HwRTPFrClassApplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RTP(Realtime Transport Protocol) Queue Configuration Information Entry."
INDEX { hwRTPFrClassApplyFrClassIndex }
::= { hwRTPFrClassApplyTable 1 }
HwRTPFrClassApplyEntry ::=
SEQUENCE {
hwRTPFrClassApplyFrClassIndex
Integer32,
hwRTPFrClassApplyStartPort
Integer32,
hwRTPFrClassApplyEndPort
Integer32,
hwRTPFrClassApplyBandWidth
Integer32,
hwRTPFrClassApplyCbs
Integer32,
hwRTPFrClassApplyRowStatus
RowStatus
}
hwRTPFrClassApplyFrClassIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Fr Class Index, equal to HwFrClassIndex."
::= { hwRTPFrClassApplyEntry 1 }
hwRTPFrClassApplyStartPort OBJECT-TYPE
SYNTAX Integer32(2000..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
RTP-PORT(3): start-port: 2000~65535
"
::= { hwRTPFrClassApplyEntry 2 }
hwRTPFrClassApplyEndPort OBJECT-TYPE
SYNTAX Integer32(2000..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
RTP-PORT(3): end-port: 2000~65535
"
::= { hwRTPFrClassApplyEntry 3 }
hwRTPFrClassApplyBandWidth OBJECT-TYPE
SYNTAX Integer32 (8..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Max bandWidth Value:
Absolute value: 8~1000000. Unit: Kbps
"
::= { hwRTPFrClassApplyEntry 4 }
hwRTPFrClassApplyCbs OBJECT-TYPE
SYNTAX Integer32 (1500..2000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"
Committed Burst Size: 1500~2000000. Unit: byte
"
::= { hwRTPFrClassApplyEntry 5 }
hwRTPFrClassApplyRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"RowStatus for RTPFrClassApply Table.
Three actions are used: active, createAndGo, destroy"
::= { hwRTPFrClassApplyEntry 6 }
-- RTPQ statistics on the Fr Pvc
hwRTPFrPvcQueueRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwRTPFrPvcQueueRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Running statistics for RTP(Realtime Transport Protocol) Queue
applied on the FR PVC"
::= { hwRTPQoSObjects 2 }
hwRTPFrPvcQueueRunInfoEntry OBJECT-TYPE
SYNTAX HwRTPFrPvcQueueRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RTP(Realtime Transport Protocol) Queue statistics entry."
INDEX { hwPvcApplyFrClassIfIndex,
hwPvcApplyFrClassDlciNum
}
::= { hwRTPFrPvcQueueRunInfoTable 1 }
HwRTPFrPvcQueueRunInfoEntry ::=
SEQUENCE {
hwRTPFrPvcQueueSize
Integer32,
hwRTPFrPvcQueueMaxSize
Integer32,
hwRTPFrPvcQueueOutputs
Counter32,
hwRTPFrPvcQueueDiscards
Counter32
}
hwRTPFrPvcQueueSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the packet number of RTP(Realtime Transport Protocol) Queue now."
::= { hwRTPFrPvcQueueRunInfoEntry 1 }
hwRTPFrPvcQueueMaxSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the Max packet number of RTP(Realtime Transport Protocol) Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 2 }
hwRTPFrPvcQueueOutputs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the Output packet number of RTP(Realtime Transport Protocol) Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 3 }
hwRTPFrPvcQueueDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the Discarded packet number of RTP(Realtime Transport Protocol) Queue."
::= { hwRTPFrPvcQueueRunInfoEntry 4 }
END