Compressor = [
1 3.5 74.4 0.1 0.35 25 153;
2 2.676 77.5 0.34 0.91 45 146.7;
3 2.697 80.5 0.89 2.40 45 147.6;
4 2.468 82.4 2.35 5.80 45 142.2;
5 1.963 83.0 5.72 11.23 45 109.1];
% No. (1) | beta (2) [-] | eta (3) [%] | In_P (4) [MPa]| Out_P (5) [MPa]| In_T (6) [C]| Out_T(7)[C]
Turbine = [
1 2.212 82.6 2.50 1.13 100 12;
2 2.8 81.0 1.12 0.40 100 13;
3 3.714 81.6 0.39 0.105 100 13];
% No. (1)|In_T_Air(2)[C]|Out_T_Air(3)[C]|In_T_Water(4)[C]|Out_T_Water(5)[C]|T_Diff_Hot(6)[C]|T_Diff_Cold(7)[C]|Mass_flow(8)[kh/h]
CoolHE = [
1 153 45 35 120 23 10 484.6;
2 146.7 45 35 120 26.7 10 456.3;
3 147.6 45 35 120 27.6 10 460.4;
4 142.2 45 35 120 22.2 10 436.2;
5 109.1 45 35 60 49.1 10 991.7];
% No. (1)|In_T_Air(2)[C]|Out_T_Air(3)[C]|In_T_Water(4)[C]|Out_T_Water(5)[C]|T_Diff_Hot(6)[C]|T_Diff_Cold(7)[C]|Mass_flow(8)[kh/h]
HeatHE = [
1 -15 100 120 35 20 50 2827.8;
2 30 100 120 35 20 5 2163.9;
3 25 100 120 35 20 10 2139.3];